– 1 109 hPSC-derived cardiomyoyctes will be required to replace
the considerable number of cells lost in a myocardial infarction
[14]. To this end, bioreactors provide a robust, efficient and scal-
able method to generate an unlimited supply of cells critical in many
clinical indications. Here, we describe the microcarrier-based
expansion of hPSCs in a 3 L bioreactor, resulting in high-fold
expansion of high quality cells within 2 weeks of culture [9]. The
cell inoculum—derived from cells cultured in 2D—are introduced
into the bioreactor with extracellular matrix-coated plastic micro-
carriers. Compared to suspension cultures which use an aggregate-
based method for expansion [7, 15], microcarriers provide a large
surface area on which cells attach and grow [9, 16].
2
Materials
Perform the procedures using aseptic technique inside a Biological
Safety Cabinet unless otherwise noted. Limit the exposure of the
L7™hPSC culture system to light. Store reagents according to
manufacturer’s instructions.
2.1
L7™TFO2 hPSC
Complete Medium
1. Thaw a 10 mL bottle of L7™hPSC medium supplement in
37 C. Add the entire contents to 1 L of L7™TFO2 hPSC
basal medium (see Note 1). Invert the bottle twice to mix and
store in 4 C until use.
2. 7 L bags of L7™TFO2 hPSC basal medium (see Note 2).
2.2
Passaging
Solutions
1. L7™hPSC passaging solution (see Note 3).
2. F3 hPSC passaging solution (see Note 4).
2.3
Buffers and
Reagents
1. Cell culture grade water.
2. Dulbecco’s Phosphate-Buffered Saline with calcium and mag-
nesium (DPBS+/+); pH 7–7.6. Store at 15–30 C.
3. Dulbecco’s Phosphate-Buffered Saline without calcium and
magnesium (DPBS/); pH 7–7.6. Store at 15–30 C.
4. 250 μg/mL L7™hPSC matrix. Add 4 mL of cell culture grade
water to 1 mg of lyophilized matrix (see Note 5).
5. 10 mM Y-27632 Dihydrochloride (Rho-associated protein
kinase (ROCK) inhibitor). Add 624.4 μL DMSO to 2 mg of
ROCK inhibitor. Mix by pipetting (see Note 6).
2.4
Tubing
1. Assemble the dip tube/perfusion line (see Fig. 1), media feed
line (see Fig. 2) and harvest line extension assembly (see Fig. 3).
Autoclave using the dry cycle (see Note 7).
40